Log File Server

PART NO. EDY-LFS-100

An on-premises log ingestion and analysis appliance that instruments every hop between plant instrumentation and enterprise analytics — so missing, stale, or silently dropped data can be located and evidenced rather than estimated.

Part Number
EDY-LFS-100
Revision
R1
Category
Diagnostic Appliance
Deployment
On-Premises
Data Flow
Read-Only
Control Authority
None
The Problem

Data that never arrives is
indistinguishable from data that says zero

Between a field sensor and a corporate analytics platform, plant data passes through a long chain of independent systems: the device itself, the control network, the SCADA platform, an OPC or tag-translation layer, one or more databases, and a transport link to the enterprise. Each hop is owned by a different vendor, configured by a different team, and logged in a different format.

When a value stops arriving, nothing fails loudly. The historian records a gap or holds the last good value. Downstream reports still generate. Availability and performance calculations still return a number — the number is simply wrong, and remains wrong for as long as nobody isolates which hop dropped it. Losses get attributed to equipment that is operating correctly, and generation revenue is reported against data that was never actually measured.

Representative field case

At a utility-scale solar site, four plane-of-array irradiance sensors were reporting no values into SCADA. Because loss attribution is calculated against measured irradiance, the absence propagated into roughly 40% of the site's performance accounting. The instruments were inexpensive and the fix was straightforward — but the fault was invisible in every dashboard that consumed the data, and it persisted through a complete SCADA platform replacement.

This is not a SCADA problem and it is usually not fixed by replacing SCADA. It is an observability gap in the chain between systems, and it persists because no single system in that chain can see the whole path.

What It Does

Instrument the whole chain, then prove where data dies

The ENERDYNE Log File Server is a dedicated on-premises appliance that collects the operational logs, event records, and data-transfer telemetry produced by every system in the plant data path. It timestamps and normalizes them into one queryable timeline, then correlates across systems to identify precisely where a value was last seen and where it stopped.

01 · FIELD
Instrumentation
Sensors, meters, relays, inverters, BMS
02 · CONTROL
SCADA / PLC
Acquisition, alarming, local historian
03 · TRANSLATION
OPC / Tag Server
Tag mapping, protocol conversion
04 · STORE
Database / Historian
Persistence, aggregation
05 · ENTERPRISE
Analytics Platform
Reporting, performance accounting
EDY-LFS-100
Log File Server
Read-only collection from every stage above
// Collection is read-only at each stage. No stage is modified, proxied, or placed in-line.

Core Capabilities

CapabilityDescription
Multi-source log ingestionCollects logs and event records from control, translation, database, and transport systems over standard mechanisms (syslog, file collection, database query, API read).
Normalization & time alignmentParses heterogeneous formats into a common schema with a single time base, so events from different systems can be compared directly.
Continuity analysisDetects gaps, stalls, frozen values, and last-known-good conditions per tag or per data stream, and reports the stage at which continuity was lost.
Chain reconciliationCompares what each stage reports receiving against what the previous stage reports sending, isolating the hop where records are lost.
Retention & replayRetains collected records for a configured period so intermittent and historical faults can be investigated after the fact.
Evidence exportProduces exportable findings suitable for root-cause documentation, vendor escalation, and process-improvement reporting.
AlertingNotifies on configured continuity conditions via on-premises mechanisms selected at commissioning.
Security Posture

Designed to be assessable

The following statements describe the capabilities and constraints of the system as designed. They are provided to support a customer's own security review. Enerdyne LLC does not assert that this product is certified or compliant under any standard; applicability of any regulatory framework is determined by the registered entity operating the facility.

Direction of data flow
Read-only. The appliance consumes logs and records produced by other systems. It issues no configuration change, no control command, and no write operation to any control system, protection device, or plant asset.
Control authority
None. The product has no supervisory function, no setpoint authority, and no ability to actuate equipment.
Configuration of other devices
Not supported. The appliance cannot modify the configuration of any other device on the network. Collection is performed using read-scoped credentials supplied by the customer.
Network placement
Deployed on a monitoring or business network segment. Not placed in-line with any control path. Does not bridge network segments.
External connectivity
No outbound connectivity is required for operation. The appliance is designed to function with all egress blocked. Any optional external integration is disabled by default and enabled only at customer direction.
Cloud dependency
None. All collection, storage, processing, and analysis occur on the appliance, on customer premises.
Automated analysis
Pattern-detection and correlation functions execute locally on the appliance. No customer data is transmitted to any external inference service. Specific analysis components are identified on the as-built configuration record supplied at commissioning.
Vendor remote access
Not required. Support model is specified per order; where remote support is elected, it uses customer-controlled and customer-revocable access. Default is on-site or customer-escorted.
Data retention
Retention period configured at commissioning. Collected data remains on the appliance under customer ownership and is disposed of per customer policy.
Software inventory
A software bill of materials for the as-built configuration is available on request.
Patching
Updates supplied as reviewed packages applied under customer change control. No automatic or vendor-initiated update mechanism.
Country of Origin

System integration, software authorship, and configuration: United States — Enerdyne LLC, a Montana limited liability company.

Hardware: assembled from commercial off-the-shelf components. The manufacturer, model, and country of origin of each hardware component are identified individually on the as-built bill of materials supplied with the delivered unit. Enerdyne does not represent the country of origin of components it does not manufacture, and supplies component manufacturers' documentation unmodified.

Specifications

Configuration

The appliance is built to order and sized to the collection volume and retention period of the target site. Final hardware selection, operating system baseline, and analysis component versions are recorded on the as-built configuration record delivered with the unit.

Form factor
Rack-mounted server appliance, sized per order
Operating system
Hardened Linux; distribution and baseline specified on the as-built record
Collection interfaces
Syslog, file-based collection, database read, HTTP/REST read
Storage
Sized to retention requirement; specified per order
Network
Ethernet; management and collection interfaces separable
Power
Redundant supply available; specified per order
Access control
Local authentication with role separation; customer directory integration optional
Audit
Administrative actions and analysis outputs recorded to a local audit log
Environment
Standard conditioned equipment room; customer provides rack, power, and network
Scope note

The Log File Server is a diagnostic instrument. It identifies and evidences where operational data is lost. Remediation of the identified fault — replacing an instrument, correcting a tag mapping, resizing a server, repairing a link — is separate scope, performed by the responsible system owner or quoted separately.

Ordering Information

Part numbers

Part NumberDescriptionScope
EDY-LFS-100ENERDYNE Log File Server — single-site licenseOne facility
EDY-LFS-500ENERDYNE Log File Server — fleet licenseMultiple facilities, quantity per agreement
EDY-LFS-100-CCommissioning, integration, and operator handoverPer deployment
EDY-LFS-100-SSupport and tuning termPer term

Procurement Description

On-premises log ingestion and analysis appliance for industrial control system data pipelines. Collects, timestamps, normalizes, and retains operational log and event data from plant control, historian, and data-transport systems for the purpose of diagnosing data-integrity and data-continuity faults between plant instrumentation and enterprise analytics. Read-only data consumer; no write path to control systems. Integrated in the United States by Enerdyne LLC, Montana.

Related

Position in the ENERDYNE stack

The Log File Server establishes trustworthy operational data capture at a single site. Where a customer subsequently wants fleet-wide historical retention and pattern-based fault analysis across that data, the ENERDYNE Virtual Plant Operator (EDY-VPO-100) operates on the same one-way capture foundation. The Log File Server is a complete product on its own and does not require the Virtual Plant Operator.